Conductor: Manufactured to SAE AS81044/12
Jacket: Irradiation Cross-Linked Modified Low Smoke Polyolefin, Compounded without Halogens
Download pdf of this page
|
| |
Applications
Electronic, communication and instrumentation: MIL-DTL-24640 Slant Sheets 1 thru 13, 25 & 26 unless noted, utilize insulated conductors manufactured to SAE AS81044/12. These constructions are all QPL listed and are not watertight. The overall jacket is an irradiation cross-linked modified low smoke polyolefin that is compounded without halogens.
|
Cable Specifications
| DX |
3 |
1 |
-01UN |
16 |
19/29 |
N |
2 Conductors, Overall Jacket |
| 4 |
-02UN |
14 |
19/27 |
| TX |
3 |
2 |
-01UN |
16 |
19/29 |
N |
3 Conductors, Overall Jacket |
| 4 |
-02UN |
14 |
19/27 |
| FX |
3 |
3 |
-01UN |
16 |
19/29 |
N |
4 Conductors, Overall Jacket |
| 4 |
-02UN |
14 |
19/27 |
| TTX |
3 & 15 |
4 |
-01UN & -02UN |
20 |
19/32 |
N |
3 & 15 Pairs, Overall Jacket |
| TTXS |
2 & 4 |
5 |
-01UN & -02UN |
20 |
19/32 |
Y |
2 & 4 Shielded Pairs, Overall Jacket |
| TTXSO |
2-10 |
5 |
-01UO thru
-04UO |
20 |
19/32 |
Y |
2,6,8 & 10 Shielded Pairs Overall Shield and Jacket |
| 2XAO |
2-40 |
6 |
-01U0 thru
-05UO |
22 |
19/34 |
Y |
2,7,10,18 & 40 Pairs Overall Shield and Jacket |
| 1XMSO |
7-70 |
7 |
-01U0 thru
-03UO |
22 |
19/34 |
Y |
7,16 & 70 Shielded Singles Overall Shield & Jacket |
| MXO |
10 & 14 |
8 |
-01UO &
-02UO |
20 |
19/32 |
Y |
10 & 14 Conductors Overall Shield & Jacket |
| 2XS |
2-30 |
9 |
-01UN thru
-08UN |
22 |
19/34 |
Y |
2,3,7,10,14,19,24 & 30 Shielded Pairs Overall Jacket |
| 2XSO |
3-30 |
9 |
-01UO thru
-06UO |
22 |
19/34 |
Y |
3,7,10,14,19 & 30 Shielded Pairs
Overall Shield & Jacket |
| MXSO |
2-37 |
10 |
-01U0 thru
-08U0 |
16 |
19/29 |
Y |
2,9,21 & 37 Conductors
Overall Shield & Jacket |
| 3XS |
7 |
11 |
-01UN |
18 |
19/30 |
Y |
7 Shielded Triads
Overall Jacket |
| 2XO |
6-77 |
12 |
-01UO thru
-06UO |
26 |
19/38 |
Y |
6,18,24,42,60 & 77 Pairs
Overall Shield & Jacket |
| 2XSXO |
4 |
13 |
-01UO |
26 |
19/38 |
Y |
4 Shielded Pairs
Overall Shield & Jacket |
| 9XS |
12 |
25 |
-01UO |
12 |
37/28 |
Y |
4 Pairs & 1 Conductor
Overall Shield & Jacket |
| 10 |
-02UO |
10 |
37/26 |
4 Pairs & 1 Conductor, using 81044/9 Components
Overall Shield & Jacket |
| 8 |
-03UO |
8 |
133/29 |
4 Pairs & 1 Conductor, using 81044/9 Components
Overall Shield & Jacket |
| 5XO |
3 |
26 |
-01UO |
16 |
19/29 |
Y |
5 Conductors
Overall Shield & Jacket |
| 4 |
-02UO |
14 |
19/27 |
| 6 |
-03UO |
12 |
37/28 |
O in Part Number indicates that the cable has an optimized shield. The optimized shield is a single braid that is constructed to provide the same shielding performance as a double braid in the MIL-DTL-24643 specification, while saving weight and reducing the cable diameter. The optimized shield provides 60 db shielding from dc to 100 MHz.
All products are manufactured to meet RoHS compliance. For exceptions, please contact our sales department at 1-866-303-9473.
|