Conductor: Silver Plated Alloy or Tin Plated Copper, Stranded
Operating Temperature:
Operating Voltage:
Insulation: Extruded Layer of Irradiated Cross-Linked ETFE
Jacket: Cross-linked ETFE Jacket Applied Over A Shield
Reference: MIL-STD-1553B |
- Applications
- Specifications
Cable Specifications
| SDBS-26SABS-70 |
10606 |
26 (19/38) |
SA |
38 AWG TC 90% |
70±5 |
30 |
.111 |
2.82 |
12.1 |
18.0 |
| SDBS-24SABS-70 |
10595 |
24 (19/36) |
38 AWG TC 90% |
70±5 |
30 |
.128 |
3.25 |
15.7 |
23.4 |
| SDBS-24SASO-77 |
8421526-2/ 10612 |
24 (19/36) |
Single Optimized |
77±5 |
30 |
.130 |
3.30 |
15.9 |
23.7 |
| SDBS-24SABS-77 |
8421526-1/ 10602 |
24 (19/36) |
38 AWG TC 90% |
77±5 |
30 |
.137 |
3.48 |
15.7 |
23.4 |
| SDBS-24SADO-77 |
8421527-1/ 10613 |
24 (19/36) |
Dual Optimized |
77±5 |
30 |
.147 |
3.73 |
24.9 |
37.1 |
| SDBS-24SAEH-77 |
8421528-1/ 10614 |
24 (19/36) |
EMP Hardened |
77±5 |
30 |
.161 |
4.09 |
29.0 |
43.2 |
| SDBS-22TCSO-77 |
8421526-3/ 10605 |
22 (19/34) |
TC |
Single Optimized |
77±5 |
30 |
.165 |
4.19 |
22.7 |
33.8 |
| SDBS-22TCDO-77 |
- |
22 (19/34) |
Dual Optimized |
77±5 |
30 |
.185 |
4.70 |
32.5 |
48.4 |
| SDBS-22TCEH-77 |
- |
22 (19/34) |
EMP Hardened |
77±5 |
30 |
.190 |
4.83 |
37.4 |
55.7 |
| SDBS-24SAEH-77 |
T-10971 |
24 (19/36) |
SA |
EMP Hardened |
77±5 |
30 |
.159 |
4.04 |
29.0 |
43.2 |
| SDBS-24SASO-77 |
T-10970 |
24 (19/36) |
Single Optimized |
77±5 |
30 |
.129 |
3.28 |
15.9 |
23.7 |
The above part numbers represent the more popular constructions. Other designs are available upon request.
All products are manufactured to meet RoHS compliance. Contact our Sales Department for additional information.
Applications
These shielded twinaxial cable constructions generally conform to the electrical transmission requirements of MIL-STD-1553B for Command/Response Multiplex Databus. Avionics, military vehicle, and C3I systems are the most common applications for this nilitary protocol standard. These databus cables are available with a variety of insulation, jacketing and shielding configurations, providing the system designer with a broad choice of alternatives.
|