Conductor: Soft Annealed Tin Plated Copper, Stranded
Operating Temperature: 105°C
Operating Voltage: 600 Volts
Insulation: Thermoplastic Polyvinylchloride Compounded for High Temperature Use
Jacket: Clear Nylon (/1) or Impregnated Glass Braid Plus Clear Nylon Extension or Nylon Braid for Larger Sizes (/2)
Reference: 5086/1 & /2 |
- Applications
- Specifications
Cable Specifications
| 50861/01-22-X |
22 |
.38 |
19/34 |
TC |
16.2 |
53.2 |
.068 |
1.73 |
4.0 |
5.95 |
| 50861/01-20-X |
20 |
.62 |
19/32 |
9.88 |
32.4 |
.078 |
1.98 |
6.0 |
8.93 |
| 50861/01-18-X |
18 |
.96 |
19/30 |
6.23 |
20.4 |
.088 |
2.23 |
8.3 |
12.3 |
| 50861/01-16-X |
16 |
1.23 |
19/29 |
4.81 |
15.8 |
.098 |
2.49 |
10.3 |
15.0 |
| 50861/01-14-X |
14 |
1.94 |
19/27 |
3.06 |
10.0 |
.117 |
2.97 |
15.7 |
23.0 |
| 50861/01-12-X |
12 |
3.08 |
37/28 |
2.02 |
6.63 |
.137 |
3.48 |
23.7 |
35.0 |
| 50861/01-10-X |
10 |
4.74 |
37/26 |
1.26 |
4.13 |
.159 |
4.04 |
35.0 |
52.0 |
| 50861/02-22-X |
22 |
.38 |
19/34 |
16.2 |
53.2 |
.073 |
1.85 |
4.2 |
6.25 |
| 50861/02-20-X |
20 |
.62 |
19/32 |
9.88 |
32.4 |
.083 |
2.11 |
6.2 |
9.22 |
| 50861/02-18-X |
18 |
.96 |
19/30 |
6.23 |
20.4 |
.093 |
2.36 |
8.6 |
12.8 |
| 50861/02-16-X |
16 |
1.23 |
19/29 |
4.81 |
15.8 |
.103 |
2.62 |
10.7 |
16.0 |
| 50861/02-14-X |
14 |
1.94 |
19/27 |
3.06 |
10.0 |
.126 |
3.20 |
16.7 |
25.0 |
| 50861/02-12-X |
12 |
3.00 |
37/28 |
2.02 |
6.63 |
.143 |
3.63 |
25.0 |
37.0 |
| 50861/02-10-X |
10 |
4.74 |
37/26 |
1.26 |
4.13 |
.189 |
4.80 |
40.1 |
60.0 |
| Sizes Listed Below Have Nylon Braid Overall |
| 50861/02-8-X |
8 |
8.61 |
133/29 |
TC |
.701 |
2.30 |
.239 |
6.07 |
66.0 |
98.0 |
| 50861/02-6-X |
6 |
13.6 |
133/27 |
.445 |
1.46 |
.293 |
7.44 |
105 |
156 |
| 50861/02-4-X |
4 |
22.0 |
133/25 |
.280 |
.919 |
.349 |
8.86 |
160 |
238 |
| 50861/02-2-X |
2 |
34.0 |
665/30 |
.183 |
.600 |
.420 |
10.7 |
245 |
364 |
| 50861/02-1-X |
1 |
41.0 |
817/30 |
.149 |
.489 |
.467 |
11.9 |
304 |
452 |
| 50861/02-1X0-X |
1/0 |
53.0 |
1045/30 |
.116 |
.381 |
0.525 |
13.3 |
392 |
583 |
| 50861/02-2X0-X |
2/0 |
67.0 |
1330/30 |
.091 |
.299 |
0.587 |
14.9 |
493 |
733 |
| 50861/02-3X0-X |
3/0 |
85.0 |
1661/30 |
.071 |
.233 |
0.640 |
16.0 |
604 |
899 |
| 50861/02-4X0-X |
4/0 |
107 |
2109/30 |
.056 |
.184 |
0.725 |
18.0 |
770 |
1146 |
All products are manufactured to meet RoHS compliance. For exceptions, please contact our sales department at 1-866-303-9473.
Applications
This general purpose PVC/nylon wiring material may be used in electrical or electronic applications. The nylon insulation jacketing material, and braid on /2, provide a very tough, abrasion resistant wire. The wire also has excellent resistance to moisture, fuels, hydraulic fluides and other common industrial solvents. This wire should be considered for use in any application where it may be exposed to abrasion, high impact loads, other mechanical damage or chemical abuse. Due to the PVC content, this wire should not be used in manned aerospace systems.
|